Desert Master™ 50TJM

Single Side Discharge Rooftop Cooling Unit
Puron® (R-410A) Refrigerant

15.0 to 27.0 nominal tons

The 50TJM units are single side discharge rooftop cooling unit utilizing electric heat as an option. Units are prewired, pre-charged with R-410A refrigerant, and tested at the factory. These units can be placed on the side of a building or can be placed on a roof without roof curbs. Each unit is designed to occupy a minimal space. Piping and drain connections are readily accessible.

Description

15.0 to 27.0 nominal tons

The 50TJM units are single side discharge rooftop cooling unit utilizing electric heat as an option. Units are prewired, pre-charged with R-410A refrigerant, and tested at the factory. These units can be placed on the side of a building or can be placed on a roof without roof curbs. Each unit is designed to occupy a minimal space. Piping and drain connections are readily accessible.

Carrier’s Package Rooftop Unit software makes selecting and optimizing the 50TJM easy.

Performance Details

  • ASHRAE 90.1 Compliant
  • EER’s up to 11.71
  • TXV refrigerant metering device
  • Two independent refrigerant circuits, each with a scroll compressor
  • Low outdoor temperature cooling operation down to 40°F
  • Cooling operating range up to 125 °F (51.6°C)
  • Liquid filter drier standard on each circuit
  • Fresh air intake capability
  • Non-corrosive sloped condensate drain pan in accordance to ASHRAE 62 standard
  • Thermally protected and permanently lubricated condenser and evaporator fan motors
  • Angle type return air section with washable type filters

Environmentally Responsible Refrigerant Choice

R-410A refrigerant is:

  • A chlorine-free refrigerant from the HFC group
  • Has zero ozone depletion potential
  • Thermally efficient and provides High EER (energy efficiency), COP, and part load efficiencies

Superior Reliability, Efficiency and Safety

  • Exceptional endurance tests
    • Painted panels tested to ASTM B-117 500 hours salt spray protection
    • Pre-coated fin condenser coil for extra corrosion protection
  • Compressor Protection:
    • High and low pressure cutouts
    • Compressor lockout
    • Phase protection relay
    • Crankcase heaters are standard for all units
    • Internal over temperature protection
    • Freeze protection
  • Low vibration design:
    • Leak-tight refrigerant circuit
    • Brazed refrigerant connections for increased leak tightness
    • Low-noise scroll compressors with low vibration levels
  • Control circuit protected by circuit breaker
  • Thermally protected and permanently lubricated condenser and evaporator fan motors
  • Angle type return air section with washable type filters
  • Transformer for safe 24v control circuit supply included
  • State-of-art scroll compressor technology
  • Dual, electrically and mechanically independent refrigerant circuit
  • Double skin construction, Insulated cabinet

Product Catalog